Complying With the OH&S Act by Testing and Tagging Electrical Appliances in Accordance of AS3760

The Occupational Health and Security Act places an obligation of care to provide a safe workplace. Failing to maintain electrical equipment in a safe condition or to use equipment in accordance with manufacturer’s instructions may cause damage or death to yourself, employees, or other functions. To satisfy the duty of
care you ought to ensure that risk of injury from lectric shock for a lot of people at the workplace is reduced as far as is reasonably practicable. A method of reaching this duty is by tests and tagging electrical equipment, and implementing procedures for use of electrical equipment. electrical test and tag

“Portable electrical equipment, including flexible cords should be regularly inspected for wear and mechanical damage, and occasionally tested for earth continuity and insulation resistance. Types of procedures for testing of electric leads, tools and equipment and the frequency of these tests can be found in: Joint Aussie and New Zealand Normal AS/NZ 3760 In-service basic safety inspection and testing of electrical equipment” 

Energy Secure Victoria, Regular Checking of Electrical Equipment, September june 2006

Inspection and Testing

Electric powered equipment needs to be Inspected and tagged on a regular basis. Home inspections should be carried out by a person certified as competent to undertake remedy. Testing and tagging has to be in accordance with the performance specifications of:

Australian Standard 3760: the year 2003 In-service safety inspection and testing of electrical equipment.

In-Service procedures

Where appropriate, in-service testing and inspection shall include:

External inspection of the equipment and the connecting facilities (eg flexible supply cord)
Protecting earth continuity tests for Class 1 equipment, electricity boards and cord units
Insulation testing, which may be achieved by testing insulation resistance, or seapage current
Confirmation of the correct polarity of live connections in cord twos with re-wireable plugs and cord extension sockets.
Bank checks for injury to flexible source cords including:

The internal cores of flexible source cords are not uncovered or twisted
The exterior sheaths of flexible source cords are not slice, abraded, twisted, or broken to such an degree that the insulation of the inner cores is visible
Unprotected conductors or maybe the use of banding efficiency tape are not in evidence.